読者です 読者をやめる 読者になる 読者になる

NS0-506 模擬試験最新版、NS0-506 資格参考書

 

NO.1 What is installed on your Linux host when you install the Linux Unified Host Utilities 7.0?
A. drivers and firmware
B. software iSCSI initiator
C. nSANity
D. SAN Toolkit data collection utility
Answer: D

NS0-506 試合   NS0-506 受験   
Reference: https://library.netapp.com/ecm/ecm_download_file/ECMP1654941

NO.2 Click the Exhibit button.
cl01::>lun resize -vserver
svm1 -volume db1_vol -lun db1
-size 4096g
Error: command failed: New
size exceeds this LUN's
initial geometry
cl01::>
What is the reason for the error shown in the exhibit?
A. The LUN is thin provisioned, but the parent volume is thick provisioned and cannot satisfy the
request.
B. The aggregate over commitment threshold has been exceeded.
C. The parent volume that contains the LUN is out of space.
D. The LUN cannot be grown past its maximum resize size.
Answer: D

NS0-506 ソフトウエア   
Reference: http://community.netapp.com/t5/VMware-Solutions-Discussions/lun-resize/td-p/8608

NO.3 You created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. The storage
efficiency savings of
the vmdks are one over 50%, but the application team wants to minimize the possibility of an out-of-
space condition.
You enable autogrow, autoshrink, and snapshot autodelete with the following commands:
volume modify -vserver vm1 -volume vol_esx_nfs1 -space-mgt-try-first volume_grow
snapshotautodelete modify -vserver vm1 -volume vol_esx_nfs1 -enabled true -delete-
orderoldest_first -target-free-space 10% -trigger volume
volautosize -vserver vm1 -volume vol_esx_nfs1 -mode grow_shrink -maximum-size 10 TB -
minimum-size 5 TB -grow-threshold-percent 80 -shrink-threshold-percent 60
What will these commands do?
A. Shrink the volume before deleting the Snapshot copies.
B. Increase the Snapshot copy reserve before growing the volume.
C. Grow the volume before deleting the Snapshot copies.
D. Delete the oldest Snapshot copies before growing the volume.
Answer: B

NS0-506 真実   

NO.4 Microsoft ODX supports which scenario on clustered Data ONTAP 8.3?
A. moving a VHDX with both SMB 3.0 and SAN protocols as either source or destination
B. moving a VHDX from a SAN LUN source to a SAN LUN destination with no SMB support
C. moving a VHDX from an SMB 3.0 source to an SMB 3.0 destination with no SAN support
D. moving a VHDX with both SMB 2.1 and SAN protocols as either source or destination
Answer: D

NS0-506 知識   NS0-506 リンクグローバル   

もしあなたはまだ合格のためにNetwork Appliance NS0-506 模擬試験最新版に大量の貴重な時間とエネルギーをかかって一生懸命準備し、Network Appliance NS0-506 模擬試験最新版に合格するの近道が分からなくって、今はJapanCertが有効なNetwork Appliance NS0-506 模擬試験最新版の合格の方法を提供して、君は半分の労力で倍の成果を取るの与えています。

NS0-506 模擬試験最新版はNetwork Applianceのひとつの認証試験でIT業界でとても歓迎があって、ますます多くの人がNS0-506 模擬試験最新版に申し込んですがその認証試験が簡単に合格できません。準備することが時間と労力がかかります。でも、JapanCertは君の多くの貴重な時間とエネルギーを節約することを助けることができます。

試験番号:NS0-506 試験攻略
試験科目:「NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP」
最近更新時間:2017-02-09
問題と解答:75

>> NS0-506 試験攻略

 

JapanCertは最新のAWS-SysOps問題集と高品質のMB2-711問題と回答を提供します。JapanCertのMB2-713 VCEテストエンジンと70-347試験ガイドはあなたが一回で試験に合格するのを助けることができます。高品質のMA0-104 PDFトレーニング教材は、あなたがより迅速かつ簡単に試験に合格することを100%保証します。試験に合格して認証資格を取るのはそのような簡単なことです。

記事のリンク:http://www.japancert.com/NS0-506.html